New 2023 Guaranteed Success with TorrentExam DCDC-002 Dumps BICSI PDF Questions [Q37-Q58]

Share

New 2023 Guaranteed Success with TorrentExam DCDC-002 Dumps BICSI PDF Questions

Exceptional Practice To BICSI Data Center Design Consultant - DCDC Pass the First Time


BICSI DCDC-002 Certification Exam is an online exam that consists of 100 multiple-choice questions. The time limit for the exam is four hours, and the passing score is 75%. DCDC-002 exam is available in English, Spanish, and Portuguese. BICSI recommends that candidates have at least five years of experience in the data center industry before taking the exam.


BICSI DCDC-002 exam is a comprehensive exam that covers a wide range of topics related to data center design, including power and cooling systems, space planning, security, cabling infrastructure, and network architecture. DCDC-002 exam is designed to test the candidate's understanding of these topics in depth, and it requires a high level of technical knowledge and expertise to pass.

 

NEW QUESTION # 37
Where should all Storage and Unpacking activities occur?

  • A. Outside the Building, at a secure location.
  • B. Inside Computer Room
  • C. Near the Main Entrance of Data Center
  • D. Outside Computer room, either in Storage Rooms or Staging Areas located adjacent to Computer Room with Dedicated air Handling
  • E. None of these

Answer: D


NEW QUESTION # 38
What is the ASHRAE min and max dew point

  • A. 42F and 65F
  • B. -10°F to +85°F
  • C. 40F and 55F
  • D. 30F and 59F

Answer: A


NEW QUESTION # 39
What is the preferred location of the power distribution unit?

  • A. inside a ventilation duct
  • B. in an unused area of another floor
  • C. under each server rack
  • D. a service gallery outside the computer room, if the A H J and feeder distances allow

Answer: D


NEW QUESTION # 40
What is the recommended range for the high temperature in a data center according to NEB?

  • A. 90 degrees
  • B. 75 degrees
  • C. 85 degrees
  • D. 70 degrees
  • E. 80 degrees

Answer: E


NEW QUESTION # 41
What is the recommended range for the high temperature in a data center according to ASHRAE?

  • A. 90 degrees
  • B. 80.6 degrees
  • C. 75 degrees
  • D. 85 degrees
  • E. 70 degrees

Answer: B


NEW QUESTION # 42
Where is the recommended location for remote power panels?

  • A. inside a sealed room
  • B. at one or both ends of an equipment row
  • C. outside the building
  • D. suspended from ceiling

Answer: B


NEW QUESTION # 43
What is recommended size ratio of Secure Storage Area?

  • A. None Of These
  • B. 10% or greater than Available Floor Space
  • C. 5% of Computer Room Space
  • D. 10% of Computer Room's Net Square Footage
  • E. 15-20% more than Computer Room's Cross Sectional Area

Answer: D


NEW QUESTION # 44
What kind of height clearance should data center access roads have?

  • A. None Of The Above.
  • B. A Minimum clear road width and sixteen (16) ft height clearance throughout.
  • C. A Minimum clear road width with fourteen (14)ft hight clearance throughout.
  • D. A Minimum clear road width and six(06) ft height clearance throughout.

Answer: C


NEW QUESTION # 45
According to NEB, what is the recommended range for the low temperature in a data center?

  • A. 60 degrees
  • B. 55 degrees
  • C. 65 degrees
  • D. 75 degrees
  • E. 70 degrees

Answer: C


NEW QUESTION # 46
What is the distance from the bottom of the access floor to the bottom of the cable tray?

  • A. 6 inches
  • B. 7 inches
  • C. 9 inches
  • D. 10 inches
  • E. 8 inches

Answer: E


NEW QUESTION # 47
How far should Data Center be located from Commercial Airport?

  • A. At Least 3 Miles
  • B. At Least 5 Miles
  • C. At least 10 miles
  • D. None of the above.

Answer: B


NEW QUESTION # 48
where should engineering offices be located?

  • A. in a separate building
  • B. far away from the data center
  • C. adjacent to equipment rooms they support
  • D. inside computer room

Answer: C


NEW QUESTION # 49
Where is temperature typically measured in a data center HVAC system?

  • A. At the server rack exhaust
  • B. At the CRAC unit exhaust
  • C. At the CRAC unit inlet
  • D. At the server rack inlet

Answer: C


NEW QUESTION # 50
What IBC occupancy category are data centers placed in if they don't have to operate after an earthquake?

  • A. Category3
  • B. Category 4
  • C. Category1
  • D. Category2

Answer: D


NEW QUESTION # 51
What is the third preference regarding electricity supply?

  • A. One Circuit From Single Sub Station Fed Via Additional Path from Alternate Power Grid
  • B. Two Balanced Feeds With Same Voltage Derived From A Single Distribution Station
  • C. At Least Two Circuits From Same Power Grid But Different Substations And Separate Paths
  • D. One Balanced Feeder Coordinated With Upstream Backup Feed

Answer: C


NEW QUESTION # 52
What is the United States Average Power Utility Outage Annually And What Is The Average Repair Time?

  • A. Three outages annually, with an unknown average repair time
  • B. 1.86 outages annually, with average repair time of four hours
  • C. 1 outage annually, with average repair time of approximately eight hours
  • D. 2.5 outages annually, with average repair time of approximately 7 hours

Answer: B


NEW QUESTION # 53
What is the recommendation regarding row length?

  • A. All
  • B. None
  • C. Ten Racks in Length
  • D. Maximum twenty-five racks in each row only
  • E. Do not exceed 20 racks in length and dead-end rows not to exceed ten racks long

Answer: E


NEW QUESTION # 54
What level should the battery room be on?

  • A. Lower Floor
  • B. All
  • C. None
  • D. Grade Level
  • E. Upper floor

Answer: D

Explanation:
Explanation


NEW QUESTION # 55
What is the minimum aisle width?

  • A. Arm span distance between technicians
  • B. The width shouldn't exceed more than half room length
  • C. 3 feet
  • D. Twice server cabinet depth

Answer: C


NEW QUESTION # 56
What are the equipment clearance/access requirements when designing the door openings and loading dock areas for a data center?

Answer:

Explanation:
Clearance requirements of 10' L x 4' W x 8' H and 7500 pounds


NEW QUESTION # 57
What is the NEBS GR-3028-CORE recommended operational temperature.

  • A. -30°F to +110°F (-34°C to +43°C)
  • B. -20°F/-28° C minimum and up to a maximum of104 ° Fahrenheit/40° Celsius
  • C. Up To140 Degrees Fahrenheit /60 Degrees Celsius
  • D. -25°F to +125°F (-32°C to +52°C)

Answer: B


NEW QUESTION # 58
......


BICSI DCDC-002 certification exam is designed for professionals who are looking to validate their expertise in the field of data center design. BICSI Data Center Design Consultant - DCDC certification is offered by the Building Industry Consulting Service International (BICSI), a professional association that provides educational and networking opportunities to information and communications technology (ICT) professionals worldwide. The DCDC certification exam covers a wide range of topics related to data center design, including the planning, design, implementation, and operation of data centers.

 

DCDC-002 EXAM DUMPS WITH GUARANTEED SUCCESS: https://www.torrentexam.com/DCDC-002-exam-latest-torrent.html

Best Quality BICSI DCDC-002 Exam Questions: https://drive.google.com/open?id=1e_PuL2xud1GOMLNq-01theMCvXBbr6p0